PAC30A/PAC60A SECLECTION TABLE
|
|||||||
Order code | Basic functions | ||||||
PAC30A- | Input signal :4-20MA (impedance 100Ω) ,0-10V DC. Output Type: regulator or cycle power adjustment, PWM power adjustment (arbitrarily set). Power-slow start, slow shutdown, radiator over-temperature alarm, manual / automatic bumpless switching. Suitable star grounded or ungrounded, Delta Connection and other resistive load. | ||||||
PAC60A- | Input signal :4-20MA (impedance 100Ω) ,0-10V DC. Output Type: regulator or cycle power adjustment, PWM power adjustment (arbitrarily set). Power-slow start, slow shutdown, radiator over-temperature alarm, manual / automatic bumpless switching. Has a current limit, overcurrent protection, can effectively control silicon carbide, electric control, transformers and other inductive loads. | ||||||
Radiator Model | Overall dimensions (mm) |
Module
|
Load power | PAC30A- | PAC60A- | ||
Specification | Unit price (Baht) | Unit price (Baht) | |||||
B30C- |
210×127×212mm | MKKT55A- | ≤13KW | ||||
Two-hole mounting, up and down the pitch 198mm | MKKT70A- | ≤13KW | |||||
MKKT90A- | ≤13KW | ||||||
B125C- An induced draft fan forced air cooling, ambient temperature 40 degrees, the maximum current of 60A per phase |
265x127x212mm | MKKT55A- | ≤26 KW | ||||
Two-hole mounting, up and down the pitch 253mm | MKKT70A- | ≤33 KW | |||||
(Selection is recommended: first re-election to elect the applicable radiator SCR) | MKKT90A- | ≤37 KW | |||||
MKKT110A- | ≤40 KW | ||||||
MKKT130A- | ≤40 KW | ||||||
B170C-An induced draft fan forced air cooling, ambient temperature 40 degrees, the maximum current of 140A per phase | 303x172x243mm | MKKT90A- | ≤46 KW | ||||
Two-hole mounting, up and down the pitch 291mm | MKKT110A- | ≤60 KW | |||||
(Selection is recommended: first re-election to elect the applicable radiator SCR) | MKKT130A- | ≤66 KW | |||||
MKKT160A- | ≤80 KW | ||||||
MKKT180A- | ≤86 KW | ||||||
MKKT200A- | ≤90 KW | ||||||
B210C-Two induced draft fan forced air cooling, ambient temperature 40 degrees, the maximum current per phase 180A | 293x246x243mm | MKKT160A- | ≤90 KW | ||||
Two-hole mounting, up and down the pitch 281mm | MKKT180A- | ≤92 KW | |||||
MKKT200A- | ≤95 KW | ||||||
B300C-Two induced draft fan forced air cooling, ambient temperature 40 degrees, the maximum current per phase 240A |
373x246x243mm | MKKT200A- | ≤120 KW | ||||
Two-hole mounting, up and down the pitch 361mm | MKKT300A- | ≤153 KW | |||||
B350C-Two induced draft fan forced air cooling, ambient temperature 40 degrees, the maximum current per phase 350A | 373x332x243mm | MKKT300A- | ≤170 KW | ||||
Two-hole mounting, up and down the pitch 361mm | MKKT500A- | ≤230 KW | |||||
B405C- Three fan forced air ventilation type, operating ambient temperature of 40 degrees, the maximum current of 450A per phase |
423x410x243mm | MKKT600A- | ≤265 KW | ||||
Two-hole mounting, up and down the pitch 411mm | MKKT800A- | ≤270 KW | |||||
(PAC30A no such function) | Overcurrent / constant current control | N- | No | ||||
C- | Containing overcurrent alarm | ||||||
Fast Fuse | N- | No | |||||
F- | Have | ||||||
Input Signal | A | 4-20mA | |||||
V | 0-10V DC | ||||||
Selection Recommendation: now elected according to the type of load control panel, then select the radiator according to the load power,
|
PAC60A Series Technical Specifications
1. SCR load control devices (SCR) module
2. phase load power 380V AC ± 10% 50HZ
3. current capacity 25A, 50A, 60A, 80A, 90A, 115A, 140A, 160A, 190A, 250A, 320A, 400A, 600A AC
4. control panel power supply and power supply:. 380V AC ± 10% 50HZ
with phase load power requirements and power consumption:5W maximum
5. fan power (according to models) need wiring: 5 and 6 six-line terminal voltage terminal block: 220V AC 50/60Hz,20W
only current:. 0.5 A or less
6. control input 4 ~ 20mA DC input impedance of 100Ω receiver
7. LED input status indicator LED indicator lights (1): red tri-color status LED (1): Green, running (with output)
yellow blinking stop (no output) Red, red and green flashing over current, thermal overtemperature alarm (no output)
8. Control phasing control: Continuous Voltage Regulation Control: resistive zero-frequency PWM modulation transfer function
power
9. Adjust the output resolution of the phase modulation 0.2 °, power adjustment 20ms
10. The phase shift range of 0 ~ 175 °, the star load (the center ground) 0 ~ 150 °
triangular center of the load or the load is not grounded star
11. Drive output with a single silicon anti-parallel thyristor module variable width pulses: 8 ° ~ 120 ° Voltage: 5V
Current: 100mA maximum
12. Manually adjust the external 10KΩ potentiometer When
13. soft start time phase modulation control, P3 potentiometer adjustments. Adjustment range: 0.2 to 120 seconds
14. slow off-time phase modulation control, 10 seconds fixed
15. The voltage limiting plate P1 potentiometer or external 10KΩ potentiometer adjustments. Adjustment range: 0 to 100%
16. heatsink over-temperature protection temperature is 80 ℃ switch, normally closed contact, the action time: <20ms
17. alarm outputs when the radiator over-temperature, over-current action when the current specifications: anormally
open contact, 1A 250VAC pure resistance Output terminal: CN2-1, CN2-2
18. When the emergency stop alarm action, control output Emergency Action time: <20ms released: After the alarm is released
into standby mode or re-power lift
19. fan control fan then 40 ℃ temperature normally open switch, when the temperature is below 40 ℃ radiator fan does not rotate,
ensuring fan life. Fan power is 220V.
20. Start / stop switch (external switch) R1 side: CN1-3 terminal, RS side: CN1-9 terminal R1 - RS side: No-voltage contact input
shorted: slow shutdown, open: Slow start
21. Adjust power / regulator / CC switch (SW1 DIP switch)
SW1-1 = ON SW1-2 = ON, the regulator + current limiting.
SW1-1 = ON SW1-2 when = OFF, + constant current limiting.
SW1-1 = OFF SW1-2 = ON, the frequency transfer function + current limiting.
SW1-1 = OFF SW1-2 = OFF be, PWM power adjustment (unlimited streaming capabilities).
22. constant current limiting control + Current restrictions: limiting the board to adjust the potentiometer P4potentiometer or
external. Adjustment range: 20% to 100%, to cancel the current limit: the P4 potentiometer to the maximum current limit
or cancel the external potentiometer.
Constant Current Control: SW1-1 = ON, SW1-2 = OFF
Constant current control, we can not accept false load debugging (because the load current is too small).
At this time, only the open-loopd
ebugging (SW1-1 = ON, SW1-2 = ON
23. Overcurrent alarm panel within the P2 potentiometer adjustments. Adjustment range: 100% ~ 150%. Overcurrent settings
: inner plate P2 potentiometer adjustments.
Overcurrent alarm: Alarm action overcurrent, tri-color light red. Action time: <20ms.
24. Work Environment
And storage temperature
Temperature range: 0 ~ +40 ℃
Humidity range: 90% RH maximum, non-condensing
Altitude: 2000m or less
Storage temperature: -10 ~ +60 ℃
Other requirements: a well-ventilated, free from direct sunlight or heat radiation, non-corrosive, flammable gas
25. Installation forms and requirements
Wall-mounted, vertically mounted, well-ventilated
26. Insulation Resistance
Dielectric strength
Insulation resistance: module output and housing, 500VDC 20MΩ minimum
Control board power supply terminal and the shell, 500VDC 20MΩ minimum
Control input and enclosure, 500VDC 20MΩ minimum
Control board input and power supply terminal, 500VDC 20MΩ minimum
Dielectric strength: between the module output and housing, 2000VAC 1 Minute
Between the control terminal and the power supply housing, 2000VAC 1 Minute